LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
CPM2C-S100C CompoBus/S Master
OMRON CPM2C-S100C Manual And Instructions
CPM2C-S100C datasheetPDF datasheet
CPM2C-S100C OPERATION MANUAL

OMRON CPM2C-S100C Product information and technical parameters:
Brand: OMRON
Name: CompoBus/S Master
Model: CPM2C-S100C
Unit: 10 points (6 inputs/4outputs); Connector model.
Inputs: 6 points at 24 VDC.
Outputs: 4 transistor sinking outputs.
Clock: Yes.
Ultra-compact, Thin-profile CPM2C CPU.
Unit with CompoBus/S Master Offering.
High-speed Bus Communications with,
No Complicated Wiring.
Ultra-compact, thin-profile design ideal for on-site,
applications.
Ultra-compact at 40 x 90 x 65 mm (W x H x D) with.
10 I/O points and CompoBus/S Master offers.
versatile expandability to construct systems.
meeting on-site needs.
A large number of expansion I/O points reduces,
system construction cost.
Up to three Expansion Terminals can be,
connected. Furthermore, CompoBus/S Remote,
Terminals can be used for expansion I/O points.
Not only in-panel wiring but also external wiring is,
simplified. Furthermore, the miniaturization of the,
control panel reduces cable, terminal block, and wiring costs.
Easy System Designing, Modification, and Expan sion.
CompoBus/S Remote Terminals with high-speed.
bus communications and no complicated wiring.
can be used as expansion terminal blocks with,
minimal modifications as long as room for,
expansion is reserved at the designing stage.
A calendar/clock ensures easy machinery control,
including data collection and error logs with date,
and time stamps. This functionality can be used as,
a weekly timer as well.

Name: Slice I/O Units; Counter Units.
Specifications: Counter inputs: 1,
External outputs: 1 NPN.
Standards: CE, UC, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CPM2C-S100C.
A wide variety of CompoNet Slave Units,
contribute to system size reduction CPM2C-S100C
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: Inputs; NPN (+ common); 8 points.
I/O connections: M3 Screw terminals CPM2C-S100C.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
Wide variety of data, such as maintenance system data,
can be collected without affecting the productivity,
of the control system.
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply CPM2C-S100C.
voltage levels, Unit wear and tear,
and equipment operating information.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier. Input 8 points corresponding to NPN (+ public)
Remote I/O terminal (transistor connector type 4 point /8 point)
Achieve business card in half the size of the connector input type
Can switch between long range / high speed communication mode.
A product with 4 points and 8 points.
Save space.
Small size of X H45mm W58mm.
Through the cable leads to the direction of the reunification of the above, can reduce the occupied area.
With input short circuit protection function.Internal I/O common: NPN.
I/O indicators: LED display (yellow). 140 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 220 g max.
Expansion functions: No.
Short-circuit protection function: Available at input,
section only (Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common tterminal is provided for,
each connector CPM2C-S100C.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
sswitch and with tool software CPM2C-S100C.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.