LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
CPM2C-S110C CompoBus/S Master
OMRON CPM2C-S110C Manual And Instructions
CPM2C-S110C datasheetPDF datasheet
CPM2C-S110C OPERATION MANUAL

OMRON CPM2C-S110C Product information and technical parameters:
Brand: OMRON
Name: CompoBus/S Master
Model: CPM2C-S110C
Unit: 10 points (6 inputs/4outputs); Connector model.
Inputs: 6 points at 24 VDC.
Outputs: 4 transistor sourcing outputs.
Clock: Yes.
Ultra-compact, Thin-profile CPM2C CPU.
Unit with CompoBus/S Master Offering.
High-speed Bus Communications with,
No Complicated Wiring.
Ultra-compact, thin-profile design ideal for on-site,
applications.
Ultra-compact at 40 x 90 x 65 mm (W x H x D) with.
10 I/O points and CompoBus/S Master offers.
versatile expandability to construct systems.
meeting on-site needs.
A large number of expansion I/O points reduces,
system construction cost.
Up to three Expansion Terminals can be,
connected. Furthermore, CompoBus/S Remote,
Terminals can be used for expansion I/O points.
Not only in-panel wiring but also external wiring is,
simplified. Furthermore, the miniaturization of the,
control panel reduces cable, terminal block, and wiring costs.
Easy System Designing, Modification, and Expan sion.
CompoBus/S Remote Terminals with high-speed.
bus communications and no complicated wiring.
can be used as expansion terminal blocks with,
minimal modifications as long as room for,
expansion is reserved at the designing stage.
A calendar/clock ensures easy machinery control,
including data collection and error logs with date,
and time stamps. This functionality can be used as,
a weekly timer as well.

Name: e-CON Connectors.
Specifications: Inputs/Outputs;
16 inputs /16 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CPM2C-S110C.
A wide variety of CompoNet Slave Units,
contribute to system size reduction CPM2C-S110C
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: I/O;
NPN (input: + common, output: - common);
16 inputs/16 outputs CPM2C-S110C.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H) CPM2C-S110C. Specifications: Outputs, NPN (- common), 16 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications. connector.
Rated I/O power supply voltage: 24 VDC.
Remote I/O Terminals with High.
Degree of Environmental Resistance.
(IP67) in Product Lineup Including.
Economical Input, Output, and Mixed I/O Models.
Common Smart Slave functionality provides strong support for equipment,
operation status monitoring and effective maintenance.
High degree of environmental resistance with dust-proof and drip-proof,
construction. (IP67)
Models with one connector for two outputs are available to make easier,
connection with hydraulic valve devices.
(Models with 16 outputs and models with 16 mixed I/O)Name: Three-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring materiall cost can be reduced CPM2C-S110C.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CPM2C-S110C.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.


...More relevant models >>>>