LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
GT1-CT01 Counter Unit
OMRON GT1-CT01 Manual And Instructions
GT1-CT01 datasheetPDF datasheet
GT1-CT01 SETUP MANUAL

OMRON GT1-CT01 Product information and technical parameters:
Brand: OMRON
Name: Counter Unit
Model: GT1-CT01
I/O classification: Counter Unit.
External I/O points: Inputs: 1, Outputs: 2.
I/O connections: Terminal block.
Operating mode: Linear counter.
A Counter Unit Supporting Encoder,
Input for Use with MULTIPLE I/O TERMINAL.
High-speed pulse with counting speed of 50 kHz.
Counting can be set to a multiplication factor of 1 or 4.
Wide range of measurement: -8,388,608 to 8,388,607.
One external input and two external outputs are available.
DIN track mounting.

Short/disconnection detection: Supported.
Specifications: Outputs, NPN (- common), 16 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring GT1-CT01.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance GT1-CT01
Single-step wiring by simply inserting pole terminals. Specifications: I/O; PNP (input: - common,
output: + common)); Input:
8 points/Output: 8 points.
I/O connections: M3 screw terminals.
Rated internal circuit power supply voltage:
Supplied from Basic Unit GT1-CT01.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals.
Easy wiring with no sharing of terminals.
Easy-to-understand wiring locations.
No relay terminal block terminals required.
Detachable cassette-type circuit sections. Name: e-CON Connectors.
Specifications: Inputs; 16 inputs; NPN;
Without Short-circuit and,
Disconnected Line Detection GT1-CT01.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit: Connector model.
I/O classification: Digital output.
Internal I/O common: NPN (- common).
I/O points: 16.
I/O connectioons: Fujitsu connector GT1-CT01.
Power supplyvoltage: 24 VDC.
I/O specification: 0.5 A, DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The ciircuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires GT1-CT01.
DIN track mounting.