DC Backup Block for S8TS Prevents 24-VDC.
Outages Due to Power Interruptions or Failures.
Supplies 24 VDC for a fixed period of time even during.
AC input outages to considerably improve system reliability.
Block Power Supply Basic Block is connected using a Bus Line.
Connector to achieve a simple system configuration.
Notification of alarms is provided by indications on the main unit.
and alarm signal output.
RoHS-Compliant.
Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.100 A; 60 Hz, 0.090 A .
Rated input: 50 Hz, 15 W ; 60 Hz, 14 W .
Rated rotational speed: 50 Hz, 2450 r/min; 60 Hz, 2700 r/min.
Maximum flow rate: 50 Hz, 2.2 m3/min; 60 Hz, 2 S8T-DCBU-01 Series. 5 m3/min.
Maximum static pressure: 50 Hz, 63.7 Pa; 60 Hz, 63.7 Pa.
Noise: 50 Hz, 39 dB; 60 Hz, 42 dB
S8T-DCBU-01 Series
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series S8T-DCBU-01 Series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Setting range: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0 S8T-DCBU-01 Series. 8 to 8 A AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. No. of poles: 4.
Connection method: Soldering.
Suitable cable dia: 3 mm (3 to 4).
Core conductor size: 0.5 max.
Suitable sheath material: PVC, PE, PUR.
Angled Connectors.
Minimum order: 50.
Round Water-resistive Smartclick.
Connecttors That Reduce Installation Work S8T-DCBU-01 Series.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates loccking S8T-DCBU-01 Series.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved.