Type: S8JC-Z series models list.
Meet the criteria: No.
Configuration: power supply with cover; DIN guide rail mounting.
Input voltage: 350W.
Output voltage: 12VDC.
Output current: 29.0A.
The new power S8JC-ZS has a CE certification mark to market.
Through the DIN guide rail installation, significant savings in time.
Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*1).
Output voltage: 24 V.
Output current: 3.75 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: Yes.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication S8JC-Z35012CD.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that
S8JC-Z35012CD
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) S8JC-Z35012CD.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Cable length L: 0.5 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: Straight.
Cable diameter: 6.0 mm dia S8JC-Z35012CD.
No. of cable cores: 2.
Cable core cross sectional area: 0.5 mm.
Cable length: 10 m.
AC.
Minimum order: 1.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Control supply voltage: 100/ 200 VAC; With voltage fluctuation compensation.
Operating current: 2 to 4 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out tthe burned element even if one heater el,
ement among several heater elements has been burned out S8JC-Z35012CD.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters S8JC-Z35012CD.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.