LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
S8FS-C05048J Switch Mode Power Supply
OMRON S8FS-C05048J Manual And Instructions
S8FS-C05048J datasheetPDF datasheet
S8FS-C05048J datasheetPDF datasheet

OMRON S8FS-C05048J Product information and technical parameters:
Brand: OMRON
Name: Switch Mode Power Supply
Model: S8FS-C05048J
Power rating: 50 W.
Input voltage: 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC*1).
Output voltage: 48 V VDC.
Output current: 1.1 A.
Built-in fan: None.
Model with terminal block facing forward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W.

Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage S8FS-C05048J.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase S8FS-C05048J
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions S8FS-C05048J. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Rated voltage: 100 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2200 r/min S8FS-C05048J.
Maximum flow rate: 50 Hz, 2.9 m3/min; 60 Hz, 3.1 m3/min.
Maximum static pressure: 50 Hz, 42 Pa; 60 Hz, 41 Pa.
Noise: 50 Hz, 47 dB; 60 Hz, 48 dB.
Weight: Approx. 3380 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Lock method: Front lock.
Pin shape: DIP pin.
Applicable wire diameter: AWG20 to 28.
DC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements annd ensure a,
94V-0 fire retardant rating S8FS-C05048J.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Coonnector Assembly: Crimping, soldering, and screw-on S8FS-C05048J.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.


...More relevant models >>>>