I/O classification: Output.
Internal I/O circuit common: NPN (– common).
I/O points: 16.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Module Type that Allows PCB Mounting.
Compact size at 60 x 16 x 35 (W x H x D).
Lineup now includes the 16-point input model and,
16-point output model. A Perfect Fit for Small Control Panels S8FS-C35005J PDF datasheet.
Coated PCBs for Better Resistance to Environment
S8FS-C35005J
Connections for Easy Wiring.
Operation possible at ambient temperatures from -40 to 70°C.
DC input supported (90 to 350 VDC).
Power Boost function at 120%.
Horizontal side-by-side mounting.
Vibration resistance to 5G, and 300-VAC abnormal,
input voltage supported for 1 second.
Complies with EN/IEC 61558-2-16 S8FS-C35005J PDF datasheet.
UL 508 Listing/UL 1310 Class 2 output standards *1,
ANSl/ISA 12.12.01.
Certification for 3,000 m altitude,
(UL/EN/IEC 60950-1 and EN 50178).
Lloyd’s, DNV GL *2.
Conforms to F47-0706.
Five years Warranty *3. Input/Output: Inputs.
Internal I/O circuit common: NPN (+ common).
I/O points: 4 points.
I/O connection method: Sensor connector.
Rated voltage for I/O power supply: 24 VDC S8FS-C35005J PDF datasheet.
Eight Waterproof Terminal Models.
Emphasizing Cost Efficiency.
Reduced Labor.
Connection using connectors reduces the lead time,
required for installation. No tools are required for,
connection to a variety of devices.
Reduced Wiring.
Signal line wiring has been reduced so that the,
Terminal can be mounted closer to sensors and,
other devices.
Relay Box not Required.
Environment-resistant, dust-tight, drip-proof,
construction (IP67) enables direct on-site,
mounting.
Easier Maintenance.
Significant reductions not only in setup time but also,
maintenance time.
Reduced Space, Improved Operability,
Compact design (160 x 54 mm (W x H)) (8-point models).
Settings and connections can be performed using,
the switch and connectors on the front side of the Terminal.
System Configuration. Control power supply voltage: 125 VDC.
Input: DC or AC (selectable), Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations S8FS-C35005J PDF catalog.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection S8FS-C35005J PDF catalog.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).