Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
Type: H5CZ.
Time specifications: Timer Mode, A-2: Power ON Delay I,
b: Repeat cycle 1, E: Interval, Z: ON/OFF-duty-adjustable flicker,
Twin Timer Mode, toff: Flicker OFF Start 1, ton: Flicker ON Start 1.
Operating modes: Timer Mode A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 K3HB-VLC-FLK1ET11 AC/DC24
K3HB-VLC-FLK1ET11 AC/DC24
External connections: 8-pin socket.
Inputs: None.
Outputs: Contact output (time-limit SPDT + instantaneous SPDT) Models with, instantaneous contact outputs K3HB-VLC-FLK1ET11 AC/DC24.
Supply voltage: 100 to 240 VAC.
Easy to Use and Easy to Read.
Basic Features.
Character height of 10 mm for better readability.
Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Safety and Reliability.
Power supply circuit and input circuits are isolated for safety and reliability.
Set value limit function prevents unexpected operation of output devices K3HB-VLC-FLK1ET11 AC/DC24.
caused by setting mistakes.
Output counter function helps in managing the service life of the Timer or,
the load.
Other Features.
Models with instantaneous contact output.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection. Type: H7CZ.
Configuration: 1-stage preset counter.
External connections: 8-pin socket.
Settings: 1-stage.
Display digits: 6 digits.
Outputs: Contact output (SPDT).
Power supply voltage: 12 to 24 VDC/24 VAC.
Easy to Use and Easy to Read.
Basic Features.
Character height of 10 mm for better readability.
Operation is simplified by the Up Key for each digit.
Safety and Reeliability K3HB-VLC-FLK1ET11 AC/DC24.
Power supply circuit and input circuits are isolated inside the Counter.
Set value limit function prevents unexpected operation of output,
devices caused by setting mistakes.
Output counter function helps inn managing the service life of the,
Counter or the load K3HB-VLC-FLK1ET11 AC/DC24.
Other Features.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection.