Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element K3HB-VLC-FLK3BT11 AC100-240 PDF datasheet.
Burnout Detector compatible with a,
wide-range of heater control methods
K3HB-VLC-FLK3BT11 AC100-240
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance K3HB-VLC-FLK3BT11 AC100-240 PDF datasheet.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Type of input: AC voltage input.
Output type: transistor; -; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K3HB-VLC-FLK3BT11 AC100-240 PDF datasheet.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNetStandard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 60-65-70-75-80-85-90V (7 shunt).
Time hopping: timing; -0.2-0.4-0.6-0.8-1.0
-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: No, and input common; there, DC operation.
Rating consumption VA: No, 6VA (input side);
Have, 2VA (input side) 10W (control power supply side).
Control: 1C, 1A AC110V 7.5Acos output with =0.4
(max 250V 825VA AC);
24V 5A L/R=7ms DC (max 125V 50W when DC).
Display: start display (LED display),
Action display (trip) manual reset.
Automatic experiment: -.
Quality: about 2kg.
External: Mount Searl N1.5.
Static voltage relay.
K2VR-S/K2VA-S type, high action reliability disk with static type UVR/OVR.
Accurate work through high reliabiliity semiconductor circuits K3HB-VLC-FLK3BT11 AC100-240 PDF catalog.
Type K2VU-S1 is the output contact, but will be closed when the voltage is not enough,
Therefore, the locking time sequence circuit of the circuit breaker is not required.
Within thhe hidden from the start to the 2S timer, can easily adjust the time K3HB-VLC-FLK3BT11 AC100-240 PDF catalog.
The control power of the relay is not needed, which avoids the trouble of wiring.