Product name: CS1 CPU Backplane.
Units cannot be mounted; 5 slots.
Appli cable CPU Unit: CS1 CPU Unit.
C200H Group-2 High density I/O Unit, No.
Yes; C200H series Special I/O Unit, No.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
26 V system, --.
Standards: U, C, N, L, CE.
Highly Reliable Process Control.
Unit type: CS1 CPU Bus Unit.
Product name:EtherNet/IP Unit.
Specifications: Communications,
cable, Shielded twisted-pair(STP),
cable Categories: 100 Ω at 5, 5e;
Communications functions, Tag Data Link,
Functions, Message Communications Functions;
Units per CPU Unit, 8 max.
No. of unit numbers allocated: 1 CS1W-BC052.
Current consumption: 5V, 0.41A; 26V, --.
Standards: UC1, N, L, CE.
Introducing the New EtherNet/IP Unit
CS1W-BC052
More Than 180,000 Words of Tag,
Data Link Capacity!
EtherNet/IP is an industrial multivendor,
network that uses Ethernet.
Managed by the ODVA (Open DeviceNet Vendors,
Association), it has open standards and is used,
with a wide range of industrial devices.
The EtherNet/IP Unit supports tag data links to,
enable sharing data between devices at Ethernet,
nodes and a message service for sending and,
receiving data when required CS1W-BC052.
The EtherNet/IP Unit supports the same FINS/UDP,
and FINS/TCP functionality as Ethernet Units. Name: CS1D Expansion Backplane.
Specifications: Applicable systems,
Duplex CPU, Single I/O Expansion System only;
Number of Power Supply Units, 2 Units max CS1W-BC052.
(for duplex operation);
Number of I/O Units, 9 Units max.
Current consumption: 5V system, 0.28A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 0 to 10 V, ±10 V,
0 to 5 V, ±5 V, 0 to 1 V, ±1 V.
Conversion speed (resolution):
40ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in costt and space compared,
with previous systems CS1W-BC052.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-BC052.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.