Product name: CS1 CPU Backplane.
Units cannot be mounted; 3 slots.
Appli cable CPU Unit: CS1 CPU Unit.
C200H Group-2 High density I/O Unit, No.
Yes; C200H series Special I/O Unit, No.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
26 V system, --.
Standards: U, C, N, L, CE.
Highly Reliable Process Control.
Unit name: Loop Control Boards.
Specifications: No. of function blocks:
50 blocks max.
Standards: UC1, N, CE.
The open nature of the PLCs is joined,
by integrating hardware, software,
and networking to meet your needs.
Increasing amounts of information,
standardization, and open standards,
form the basis for achieving hardware,
and networking capabilities for process control CS1W-BC032
CS1W-BC032
A wide range of software that can be easily,
used by design, development, and maintenance,
personnel makes operating and maintaining,
the system far easier. Unit type: CS1 Special I/O Units.
name: Position control unit.
Specifications: Control method/Control,
output interface,Open-loop control by,
pulse train output/Line-driver output;
Number of control axes, 1 axis CS1W-BC032.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: U, C, N, L, CE.
High-speed, High-precision,
positioning with 1, 2, or 4 axes.
Versatile functions and superb,
performance enable the construction,
of compact, high-performance machines.
With its ultra-compact size of 31×90mm,
(W×H),this highly space-efficient Position,
Control Unit(PCU) enables up to 4 axes,
of motor control CS1W-BC032. Name: CS1D CPU Unit for Single CPU Systems.
Specifications: Number of I/O points,
1280 points (3 Racks);
Program capacity, 30 Ksteps;
Data Memory, 64 Kwords(DM: 32 Kwords,
EM: 32 Kwords×1 bank);
LD execution time, 0.04 μs;
Duplex CPUs, --;
Interrupt functions, OK.
Current consumption: 5V system, 0.78A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
250 ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in costt and space compared,
with previous systems CS1W-BC032.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-BC032.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.