Power ratings: 150 W.
Output voltage: 5 V.
Output current: 30 A.
Boost current: --.
Newly Released High-capacity 240-W Models in S8EX-series Lineup.
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models.
Lineup of models with from 5 to 48-VDC output.
voltages.
All Models
EE-SX4235A-P1
Approved standards:
UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC.
Complies with harmonic current standard in EN.
61000-3-2 (50-W to 240-W models).
The top class in industry for compact size.
Boost current output (some models excluded). Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages.
Performs continuous monitoring and detection of ground faults,
in low-voltage circuits due to the deterioration of insulation in,
electrical devices.
Higher reliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutually compatible.
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease. The main body: with shell type / socket terminal type.
Category: action device built in.
Pole number: 3 pole.
A variety of eight pin pin type electric power.
With shell models have AC4 rated specifications (50/60Hz AC200/220V, 50/60Hz AC100/110V).
Installation, wiring convenient, easy to operate.
Has more than 5 million mechanical life, durable.
Standard type, with shell type, special contact specifications, double contact type, double coil latch type, etc., the product is complete. Analog I/O terminal with screw terminal,
block for EtherCAT communicaitons.
The input/output range can be easily,
changed by the setting with the switch.
Detachable screw terminal block,
facilitates the maintenance.
Moving average calculation function.
Settings within the range of 100μs-64ms.
(For input only.)
Disconnection detection function.
(For input only and for usage with,
1-5V or 4-20mA ranges.)
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.
EE-SX4235A-P1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=EE-SX4235A-P1&select=5