Category: incidental cover type.
Structure: DIN guide rail mounting type.
Capacity: 30W.
Output voltage: 5V.
Output current: 6A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity
E3X-ZT41 2M
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"
Field of view: Wide View (Short-distance).
Number of pixels: 760,000 pixels.
Monochrome: NPN.
Field of view/Installation distance: Refer to figure 8 on p.20.
Inspection capabilities, camera options,
and communication options -- this powerful,
heavy weight has it all.
This Vision Sensor provides all of the best-selling,
features found in high-end models without the,
need as in vision system for a separate controller.
This new Smart Camera was designed to attract,
potential customers to try the FQ2 Series. Unit type: CS1 Special I/O Units.
Name: High speed Counter Units.
Specifications: Countable channels,
2; Encoder A and B inputs,
pulse input Z signals, Open collector,
Input voltage: 5VDC,12VDC, or 24VDC,
(only 1 axis for 5 V or 12 V input),
RS-422 line driver;
Max. counting rate, 50kHz, 500kHz.
No. of unit numbers allocated: 4.
Current consumption: 5V, 0.36A; 26V, --.
Standards: UC, N, L, CE.
High-Speed, Flexible Control With A,
Wide Array of Features.
Equipped with 2 or 4 Counters and counts,
over a maximum binary range of 32-bits.
Accepting input pulse frequencies of up,
to 500 kHz allows precise control of fast motions.
The Unit is equipped with 4 Digital Inputs,
4 Digital Outputs and 28 Soft Outputs.
A maximum response time of 0.5 ms guarantees,
high-speed closed loop control of applications.
E3X-ZT41 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E3X-ZT41 2M&select=5