Control output: linear current output.
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type
E3X-ZT11 2M
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm). Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 3.
Control output: Relay output.
Functions: Heater burnout, No; Mounting option units, No.
Previous model: E5AZ-R3 E5AZ-A3 + E53-AZR.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the,
models with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Unit type: CJ1 CPU Bus Unit.
Product Name: FL-net Unit.
Specifications:Communications interface,
100Base-TX; Communications functions,
With FL-net Ver. 2.0 specifications,
(OPCN-2) Data links and message service,
Max. Units mountable per CPU Units, 4.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.37A; 24V,--.
Standards: UC1, CE.
Connect to Multivendor Controller Networks.
This Unit allows you to connect to FL-net,
an open network based on Ethernet.
Multivendor FL-net networks can be built,
to combine CJ series PLCs with CNC machines,
robots, and PLCs from other manufacturers.
E3X-ZT11 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E3X-ZT11 2M&select=5