Type of drive rod: plunger type.
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (2NC).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC).
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm
D4NL-1AFG-B4
Elevator and escalator can be used. Actuator: Roller lever: R38.
Item: High-precision.
Connector shape: Threaded (M12).
Built-in switch type: Airtight.
Voltage: AC.
Wiring locations: NC + NO 4 core.
Connector pin No: NC 1 2; NO 3 4 .
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches.
Standard-feature gold-clad crossbar contacts provide high reliability.
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models. Fitting materials: Stainless steel (SUS304).
Count: 1 .
Accessories: Description, Nut plate;
Material, Stainless steel (SUS304);
Count, 1.
Applicable sensor (mounting pitch on sensor side): E3T-S (9/15).
Page: Dimensions, 12. A strong support for the construction of power consumption monitoring system!
1 buttons to easily focus on 31 sets of KM series machine.
With the software to easily save data graphics.
The KM connection can be easily set with special software. Actuator: One-way roller arm lever (horizontal).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.
D4NL-1AFG-B4 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4NL-1AFG-B4&select=5