Capacity: 480 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Maximum cutoff output current (per branch): 3.8 A.
Total output current: 20 A.
Number of output branches: 8 branch outputs.
Communications functions: RS-485.
Parameter settings: Changeable .
A New Type of Power Supply That.
Provides Safety and Maintainability.
240- and 480-W power supplies with and digital circuit,
protectors in a single package
MYQ4 DC24
Each branch output tripping current value can be easily,
set at 0.1-A increments.
Startup and shutdown sequence control included.
Various monitor displays and alarms (output voltage,
output current, maintenance forecast monitor,
temperature).
Conforms to UL Class 2.
Mounts to DIN Rail. Actuator: Roller lever (resin lever, bearing roller).
Conduit size: 1-conduit; M12 connector.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
MYQ4 DC24 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MYQ4 DC24&select=5