LK Automation Limited LK Automation Limited
Information sort OMRON
Home >> Supply
C500-PS212 OMRON C500-PS212 Expansion I/O Backplane Power

Name: e-CON Connectors.
Specifications: Inputs; 32 inputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced C500-PS212.
Bit-level I/O distribution reduces,
wiring in the system.
A wide vvariety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site C500-PS212.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.
Model : C500-PS212.
Expansion I/O Backplane Power Supply
24 VDC.
Output ratings: 7 A, 5 VDC C500-PS212.Model: C200H-ME832.
Description: EEPROM, 8K words, battery back-up.with clock(CPU21, CPU23 only).Product name: N@@S1- type CPU Units with 40 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 24; Outputs, 16;
Output type: Relay.
Program capacity: 8K steps OMRON C500-PS212.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0.21A; 24 V,0.09A.
Standards: CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality OMRON C500-PS212.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Name: SYSMAC LINK Module.
Model: C200HW-SLK23.
Communications method: N: N token bus OMRON C500-PS212.
Transmission method: Manchester code, base band.
Transmission path: Bus.
Weight: 400 g max.Model: CPM2A-20CDT1-D. Power supply: DC power supply.
Output type: Transistor sourcing.
Inputs points: 12 points.
Outputs points: 8 points.Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications,
Units High-speed type.
Specifications:Communications Interface,
1 RS-232C port and 1 RS-422A/485 port;
Communications functions,
The following functions can be selected,
for each port with an CJ system:
Protocol macro, Host Link, NT Links (1:N mode),
Serial Gateway, No-protocol, Modbus-RTU Slave,
The following functions can be selected,
for each port with an NJ system: Protocol macro,
Serial Gateway, No-protocol, Modbus-RTU Slave.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.36A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol C500-PS212.
Related supply information