Due to the use of the SYSNET link unit,
Making the N:N maximum capable of connecting 126 sets of PC communications becomes possible,
High speed long distance optical cable.Model : C500-PRW06.
C500-AD Special I/O Unit Analog Input C500-AD101.
Input: 8 pts.
Specification: 0~+10V、4~20mA C500-AD101.I/O bits: 1, 280 (Expan-sion Racks: 3).
Program capacity: 30K steps.
Data memory capacity: 64K words (DM: 32K words, EM: 32K words ×1 bank)I/O Slave Unit.
Number of words: 64Output type: Relay
C500-AD101.
Inputs points: 12 points.
Outputs points: 8 points.Model : CV500-CPU01-V1.
SFC / Ladder 512 (with RAM30K words, the top internal link).Product name: N@@-type CPU Units with 60 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 36; Outputs, 24;
Output type: Relay C500-AD101.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0.21A; 24 V,0.13A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient OMRON C500-AD101.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Number of inputs: 8 pts OMRON C500-AD101.
Input Voltage: 100 to 120V DC.
Input Current: 5 mA.Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, ±5 V, 0 to 10 V, ±10 V.
Conversion speed (resolution):
100ms/4 inputs OMRON C500-AD101.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems C500-AD101.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.