C500-PID01 OMRON C500-PID01

C500-OA I/O Unit Triac Output 16 pts C500-OA222(3G2A5-OA222).
AC132V 1A.Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 inputs ; 2 outputs.
Signal range selection:
Set separately for each input and output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA C500-PID01.
Resolution: 1/4,000 (Settable to 1/8,,000).
Conversion period: 1 ms/point,
(Settable to 500 μs/point).
Accuracy at ambient temperature of 25°C:
Voltage: ±0 C500-PID01.2% of F.S. Current: ±0.2% of F.S;
Voltage: ±0.3% of F.S. Current: ±0.3% of F.S.
External connection: Removable terminal block.
External power supply: 24 VDC +10% -15%, 140mA max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0 C500-PID01.58A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals OMRON C500-PID01.
Power supply: AC power supply.
Output method: Transistor output source type.
Inputs points: 12 points.
Outputs points: 8 points.Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications,
Units High-speed type.
Specifications:Communications Interface,
2 RS-422A/485 ports; Communications functions,
The following functions can be selected,
for each port with an CJ system:
Protocol macro, Host Link, NT Links (1:N mode),
Serial Gateway, No-protocol, Modbus-RTU Slave,
The following functions can be selected,
for each port with an NJ system: Protocol macro,
Serial Gateway, No-protocol, Modbus-RTU Slave OMRON C500-PID01 OMRON C500-PID01.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.40A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol. UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min C500-PID01.
No. of I/O points: 1, 184 points.
Max. no.of con-necting Expansion I/O Racks: 3 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.