C500-OD217 OMRON C500-OD217

UM: 7.2K words.
DM: 6K words.
EM: --.
Instruction processing time (basic instructions): 0.3 micro s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no C500-OD217. of con-necting Special I/O Units: 10.
RS-232C: NO.C500-AD Special I/O Unit Analog Input C500-AD101.
Input: 8 ptss.
Specification: 0~+10V、4~20mA.
Model: CPM2C-PA201. Input: 100 to 240 V AC.Output: 24 V DC/600 mA.CPU Unit: CP1H-XA CPU Units C500-OD217.
Specifications: CPU type, Memory capacity: 20K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Analog inputs: 4, Analog outputs: 2;
Power supply, DC power supply; Output method, Transistor output (sinking);
Inputs, 24; Output, 16 C500-OD217.
Standards: UC1, N, L, CE.
4 Axis Position Control and Comprehensive Programmable Controller.
The CP1H-X with pulse outputs for 4 axes.
The CP1H-Y with 1-MHz pulse I/O.
The CP1H-XA with pulse outputs for 4 axes and built-in analog I/O OMRON C500-OD217. Name: RS-422A Converter.
Specifications:
Converts RS-233C to RS-422A/RS-485.
Standards: UC1, N, L, CE.
The RS-232C port of the SYSMAC series,
can be changed into RS-422A/485 port.
The CJ1W-CIF11 RS-422A Converter connects,
directly to a CS/CJ-series RS-232C port and,
converts RS-232C to RS-422A/485 OMRON C500-OD217. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B OMRON C500-OD217.
Conversion speed: 250 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems C500-OD217.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.