C500-IA121 OMRON OMRON C500-IA121

Name: Bit Slave Units with e-CON Connectors.
Specifications: Outputs; 2 outputs; PNP.
Simple and Intelligent Bit Slaves,
with Industry-standard e-CON connectors.
Slave Units capable of 2-point bit-level distribution.
The I/O power supply is supplied from the communications,
power in the previously connected flat cable, and has a,
short-circuit detection function for protection C500-IA121.
Industry-standard e-CON connectors.
Short-circuit protection safeguards the network,
from I/O short circuits C500-IA121.
Simple communications connections,
with flat cable and connectors.
Bit-level distribution to support,
essentially any application. Type: CS Special I/O Unit.
Connected ID System: V680 Series; 2 Heads.
External power supply: 24VDC.
No. of unit numbers used: 2 unit number C500-IA121.
Current consumption: 5V, 0.32A;
24V, --; External, 0.36A.
Communication Unit Dedicated for RFID V680,
Allowing Direct Connection to OMRON PLC CJ/
CS/NJ-series.
Communication unit for connecting RFID V680-series,
which can be used around the world, directly to PLC OMRON C500-IA121.
Allows batch transfer of data up to 32 kbytes.
Name: Remote I/O Master.
Model: C200HW-SRM21-V1.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input OMRON C500-IA121.
Signal range: 4 to 20 mA, 1 to 5 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE OMRON C500-IA121.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems C500-IA121.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.