LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
XWT-OD08-1 Expansion Units
OMRON XWT-OD08-1 Manual And Instructions
XWT-OD08-1 datasheetPDF datasheet
XWT-OD08-1 PROGRAMMING MANUAL
XWT-OD08-1 INSTRUCTION Manual

OMRON XWT-OD08-1 Product information and technical parameters:
Brand: OMRON
Name: Expansion Units
Model: XWT-OD08-1
Name: Expansion Units.
Specifications: Outputs;
8 outputs; PNP;
One Expansion Unit can be,
mounted to one CRT1-ID16(-1),
CRT1-OD16(-1), CRT1-ROS16,
or CRT1-ROF16 Digital I/O Slave.
Standards: CE, UC, UC1, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.

Short/disconnection detection: Supported.
Specifications: Outputs, PNP (+ common), 32 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring XWT-OD08-1.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance XWT-OD08-1
Single-step wiring by simply inserting pole terminals. Input capacity: 16 points.
Internal I/O common: PNP.
ON voltage: 15 VDC min.
(between each input terminal and the G terminal)
OFF voltage: 5 VDC max.
(between each input terminal and the G terminal)
OFF current: 1 XWT-OD08-1. 0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms, 1 ms,
2 ms, 4 ms, 8 ms, 16 ms, 32 ms. (Default setting: 1 ms)
Number of circuits per common: 8 points/common.
Input indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply XWT-OD08-1.
Input device supply current: 100 mA/point.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current consumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 370 g max.
Expansion functions: No.
Short-circuit protection function: No.
A common terminal is provided for each contact.
It eliminate the needs for relay terminal blocks.
It is unnecessary to share the common terminal,
among multtiple contacts XWT-OD08-1.
Easy-to-find wiring locations.
Detachable screw terminal block facilitates the maintenance.
Input response time can be switched for high-speed processing.
Selectable node address setting methods: setting with rotary,

switch and with tool software XWT-OD08-1.
When setting the nodes with rotary switch, setting is easy and,
node identification becomes possible for maintenance.


...More relevant models >>>>
Last one: OMRON XWT-OD08
next one: OMRON XWT-ID16