Input/Output: Outputs.
Internal I/O circuit common: NPN (– common).
I/O points: 8 points.
I/O connection method: Sensor connector.
Rated voltage for I/O power supply: 24 VDC.
Eight Waterproof Terminal Models.
Emphasizing Cost Efficiency.
Reduced Labor.
required for installation. No tools are required for,
connection to a variety of devices.
Reduced Wiring.
other devices.
Relay Box not Required.
mounting.
Easier Maintenance.
maintenance time.
Compact design (160 x 54 mm (W x H)) (8-point models).
the switch and connectors on the front side of the Terminal.
System Configuration.
Short/disconnection detection: Supported.
Specifications: Outputs, PNP (+ common), 32 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring SRT2-OD08CL.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance
SRT2-OD08CL
Single-step wiring by simply inserting pole terminals. I/O classification: Input.
Internal I/O circuit common: NPN (+ common).
I/O points: 16.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Module Type that Allows PCB Mounting.
Compact size at 60 x 16 x 35 (W x H x D) SRT2-OD08CL.
Lineup now includes the 16-point input model and,
16-point output model. Name: e-CON Connectors.
Specifications: Inputs; 16 inputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system SRT2-OD08CL.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: Inputs; NPN (+ common);
16 points.
I/O connections: M3 screw terminals.
Rated internal circuit power supply voltage:
Supplied from Basic Unit.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals.
Easy wiring with no sharing of terminals.
Easy-to-understand wiring locations.
No relay terminal block terminals required.
Detachable cassette-type circuit sections. I/O classification: Input and output.
Internal I/O circuit common: PNP (input: – common; output: + common).
I/O points: 32.
I/O connection meethod: MIL connector SRT2-OD08CL.
Rated voltage for communications power supply: 24 VDC.
Rated voltage for I/O power supply: 24 VDC.
Applicable relay: G3DZ-2R6PL.
Subminiature 32-point Remote Terminal with Connectors.
Compact dimensions: 35 × 660 × 80 (W × D × H) SRT2-OD08CL.
Long-distance and high-speed communications modes available.
Downsizing enabled with 32-point MIL connector for I/O connection.