LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
SRT2-ID04CL-1 Waterproof Terminals
OMRON SRT2-ID04CL-1 Manual And Instructions
SRT2-ID04CL-1 datasheetPDF datasheet
SRT2-ID04CL-1 HOST CONNECTION MANUAL
SRT2-ID04CL-1 User's Manual

OMRON SRT2-ID04CL-1 Product information and technical parameters:
Brand: OMRON
Name: Waterproof Terminals
Model: SRT2-ID04CL-1
Input/Output: Inputs.
Internal I/O circuit common: PNP (– common).
I/O points: 4 points.
I/O connection method: Sensor connector.
Rated voltage for I/O power supply: 24 VDC.
Eight Waterproof Terminal Models.
Emphasizing Cost Efficiency.
Reduced Labor.
Connection using connectors reduces the lead time,
required for installation. No tools are required for,
connection to a variety of devices.
Reduced Wiring.
Signal line wiring has been reduced so that the,
Terminal can be mounted closer to sensors and,
other devices.
Relay Box not Required.
Environment-resistant, dust-tight, drip-proof,
construction (IP67) enables direct on-site,
mounting.
Easier Maintenance.
Significant reductions not only in setup time but also,
maintenance time.
Reduced Space, Improved Operability,
Compact design (160 x 54 mm (W x H)) (8-point models).
Settings and connections can be performed using,
the switch and connectors on the front side of the Terminal.
System Configuration.

Input capacity: 32 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the G terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common SRT2-ID04CL-1.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation SRT2-ID04CL-1
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 100 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 210 g max.
Expansion functions: No SRT2-ID04CL-1.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing SRT2-ID04CL-1.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance. Specifications: Inputs; NPN (+ common);
16 points.
I/O connections: M3 screw terminals.
Rated internal circuit power supply voltage:
Supplied from Basic Unit.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals.
Easy wiring with no sharing of terminals.
Easy-to-understand wiring locations.
No relay terminal block terminals required.
Detachable cassette-type circuit sections. Unit type: 10 I/O points 6 inputs; 4 outputs, Connector.
Input: 6 points: 24 VDC.
Output: 4 points: transistor (sinking).
Clock: Yes.
Slaves with the Complex Functionality Needed,
for Distributed Blocks.
Programmable Slaves combine devices, such as sensors and actuators,
into one functional unit that is treated as a DDeviceNet slave SRT2-ID04CL-1.
Programmable Slaves greatly facilitate device distribution,
and functional organization.
They help standardize programming between units and reduce the amount of,
programming required at the master.
I/O and operattional checks can be performed for each functional unit,
rather than waiting SRT2-ID04CL-1.
for final system assembly, as with conventional distributed I/O systems.


...More relevant models >>>>
Last one: OMRON SRT2-ID04CL
next one: OMRON SRT2-OD04CL