S8VS-24024BE Switch Mode Power Supply
OMRON S8VS-24024BE Manual And Instructions
S8VS-24024BE datasheetPDF datasheet

OMRON S8VS-24024BE Product information and technical parameters:
Brand: OMRON
Name: Switch Mode Power Supply
Model: S8VS-24024BE
Power ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 10 A.
Alarm output *2: --.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)

Control voltage: 200/220/240 VAC.
Reset: Manual.
Model: Instantaneous type (See note 1.).
Solid-state Relay Provides Three Operating.
Functions in a Compact Package.
Prevents burnouts in 3-phase induction motors due to overcurrent,
open-phase, or reverse-phase.
LEDs indicate operation of the selected operating function S8VS-24024BE.
Wide setting ranges: current: 1 to 160 A; operating time: 1 to 40 s S8VS-24024BE
Protects the motor from reversing without starting it.
before using the K2CM. Control voltage: 100/110/120 VAC.
Reset: Automatic.
Model: Inverse type.
Solid-state Relay Provides Three Operating.
Functions in a Compact Package.
Prevents burnouts in 3-phase induction motors due to overcurrent,
open-phase, or reverse-phase S8VS-24024BE.
LEDs indicate operation of the selected operating function.
Wide setting ranges: current: 1 to 160 A; operating time: 1 to 40 s.
Protects the motor from reversing without starting it.
before using the K2CM. Appearance: there are F4 shell, R2 shell.
Circuit structure and open circuit mode: constant circuit contact, secondary current circuit breaker.
Rated current: AC5A S8VS-24024BE.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit element time to adjust the degree 0.25-0.5-1-2-3-4-5-6-7-8-9-10,
12 nominal action time to adjust the scale of 10300% over current, 10s plus or minus 5%,
700% over current, 1.52s plus or minus 7%; instantaneous elements, nominal action time 200% over current 40ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: AC12V, 60A (CT secondary current) 100 times; AC20V, 100A (CT secondary current) 3 times.
Contact: AC110V, 7.5A, COS with =0.4; (AC250V 825VA)
DC24V, 5A, L/R=7ms (maximum 50W time DC125V).
Automatic experiment: No.
Display: start display (LED), after the time display (LED).
Output display, trip (R phase and T phase) manual reset type, instant manual reset type.
Excitation surge current suppression (fuzzy inference): -.
Quality: about 1.3KG (R2 shell), about 1.8kg (F1 shell), about 3.3kg (D2 shell).
External: Mount Searl N1.5.
Static type over current relay K2CA-D type, attention to the protection of the coordination of static type OCR.
The protection coorrdination between OCR and MCCB is simple S8VS-24024BE.
1 sets of three-phase protection, can save space and manpower.
Compared with the plate movement start display, through time display, make maintenance and inspection becomes simple.
The display oof the accident occurrence phase is used to facilitate the inspection after the accident S8VS-24024BE.
Reduce the consumption of VA, reduce the burden of converter.