Category: incidental cover with under voltage detection function.
Structure: bottom mounting type.
Capacity: 100W.
Output voltage: 24V.
Output current: 4.5A.
Alarm output: leakage type.
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
Power failure detection function with built-in hint output voltage abnormity.
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)"
Power ratings: 15 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 24 V.
Output current: 0.65 A.
Boost Current: 0.78 A.
Reliable and Easy Operation-Worldwide Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market S8VM-10024A.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC).
DC input can be available: 90 to 350 VDC
S8VM-10024A
Possible for 2-phase input usage.
Wide operation temperature range: –40 to 70 °C.
Power Boost function at 120%.
Safety standards:
UL508/60950-1, CSA C22.2 No. 107.1/60950-1.
EN50178, EN60950-1.
Lloyd’s standards, EN60204-1 PELV.
Safety of Power Transformers: EN61558-2-16 S8VM-10024A.
ANSI/ISA 12.12.01 (excluding 480-W models).
CSA C22.2 No.213 (excluding 480-W models).
15-W,30-W, and 60-W models conform to.
UL Class 2 output Standards.
EMS: EN 61204-3.
EMI: EN 61204-3 Class B.
Three years Warranty *1. Setting range: 10 to 100 A AC, 20 to 200 A AC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment S8VM-10024A.
Monitor for overcurrents or undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Input voltage: DC10-60V.
Output current: 20 A.
Contribute to build high reliable systems.
Compact and Cost-effective solution.
for Back-up applications.
Easy setup for system reliability.
requirement.
Redundancy operating LED for the status confirmation.
A signal output for failure detection of power supplies.
By adjustingg the power supply voltage to light up Balance LED,
the lifetime of power supplies will be more than twice S8VM-10024A.
Wide range input.
DC5-30V (S8VK-R10), DC10-60V (S8VK-R20).
Wide operation temperature range: -40 to 70 °C.
Safety standards::
UL508/60950-1, CSA C22 S8VM-10024A. 2 No. 107.1/60950-1.
EN50178, EN60950-1 Lloyd''s standards *2.
EMS: EN61000-6-2.
EMI: EN61000-6-3.
Six years warranty *3.