Power ratings: 960 W.
Input voltage: 3-phase, 380 to 480 VAC; 2-phase, 380 to 480 VAC.
Output Voltage: 24 V; 24 V.
Output current: 40 A; 32A.
Boost Current: 48 A; --.
Worldwide 3-phase Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market.
380 to 480 VAC (320 to 576 VAC).
380 to 480 VAC (340 to 576 VAC).
When using the 960 W at 2-phase input, the power rating is 768 W.
450 to 600 VDC (450 to 810 VDC).
Excluding 960 W.
High efficiency 91% typ. at 480 W model.
Wide operation temperature range: –40 to 70°C.
Power Boost function at 120%.
Meets LR maritime standards.
EMS: Conforms to EN 61204-3.
EMI: EN61204-3 Class B.
RoHS Compliant.
Power rating: 200 W.
Input voltage: 100 to 120 VAC, 200 to 240 VAC (allowable range: 90 to 132 VAC,
180 to 264 VAC, or 254 to 373 VDC(Select with the switch.)*2).
Output voltage: 36 V VDC.
Output current: 5.9 A.
Built-in fan: None.
Model with terminal block facing forward.
High Reliability at a Reasonable Cost S8VK-T96024.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation
S8VK-T96024
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications S8VK-T96024.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control S8VK-T96024.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF contrrol, phase control, and cyclic control S8VK-T96024.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads S8VK-T96024.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).