Input voltage: 24 VDC (24 to 28 VDC).
Output voltage(during backup operation): 22.5 V.
Output current: 2.5 A.
and Other Problems Resulting from Momentary.
Power Failures.
Provides a backup time of 500 ms at an output current of 2.5 A.
Can be wired to the 24-V output from the S8VS Supplies.
Connects to an S8TS Power Supply via an S8T-BUS03 Bus Line Connector.
the backup time and current capacities.
Complies with SEMI F47-0200 standard.
RoHS-compliant.
Ambient operating temperature range of –20 to 60°C.
Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.085 A; 60 Hz, 0.070 A .
Rated input: 50 Hz, 7 W ; 60 Hz, 6 W .
Rated rotational speed: 50 Hz, 2600 r/min; 60 Hz, 3000 r/min.
Maximum flow rate: 50 Hz, 0.6 m3/min; 60 Hz, 0 S8T-DCBU-02. 7 m3/min.
Maximum static pressure: 50 Hz, 39.2 Pa; 60 Hz, 53.9 Pa.
Noise: 50 Hz, 32 dB; 60 Hz, 36 dB
S8T-DCBU-02
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series S8T-DCBU-02.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Type: With cable.
Connector: Connectors on both cable ends S8T-DCBU-02.
DC: Cable length L, 2 m; Minimum order, 5.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is iindicated from the start of operation S8T-DCBU-02.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions S8T-DCBU-02. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.