LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
S8FS-C07515J Switch Mode Power Supply
OMRON S8FS-C07515J Manual And Instructions
S8FS-C07515J datasheetPDF datasheet
S8FS-C07515J datasheetPDF datasheet

OMRON S8FS-C07515J Product information and technical parameters:
Brand: OMRON
Name: Switch Mode Power Supply
Model: S8FS-C07515J
Power rating: 75 W.
Input voltage: 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC*1).
Output voltage: 15 V VDC.
Output current: 5 A.
Built-in fan: None.
Model with terminal block facing forward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W.

Model: RPR (67P).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular S8FS-C07515J.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system S8FS-C07515J
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries S8FS-C07515J.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring S8FS-C07515J. Type: Spot lens.
Spot: Spot dia.: 10 mm.
Cost Revolution Led by UV Curing.
System.
Minimal heat damage thanks to UV-LED irradiation.
New UV LEDs with much higher brightness mounted in heads.
Greater irradiation power to reduce bonding tact time.
Usage of LEDs that have a long lifetime of 40,000,
hours* drastically reduces running costs.
Ultra compact body that is approximately 1/8th the size,
of a conventional lamp system.
Equipped with a color LCD that makes settings simple and reliable. Rated voltage: 230 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.220 A; 60 Hz, 0.190 A .
Rated input: 50 Hz, 50 W; 60 Hz, 48 W.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3100 r/min.
Maximum flow rate: 50 Hz, 4.8 m3/min; 60 Hz, 5.7 m3/min.
Maximum static pressure: 50 Hz, 104 Pa; 60 Hz, 107 Pa.
Noise: 50 Hz, 56 dB; 60 Hz, 58 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and mettal-bladed models,
(28 type) included in series S8FS-C07515J.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certiffied safety standards depend on the,
product S8FS-C07515J. Check the information given for available models of Axial fans and,
the information in Characteristics.


...More relevant models >>>>