Power rating: 25 W.
Input voltage: 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC*1).
Output voltage: 5 V VDC.
Output current: 5 A.
Built-in fan: None.
Model with terminal block facing forward.
High Reliability at a Reasonable Cost.
Contribute to Stable Equipment Operation.
operation even with an unstable input voltage.
to achieve stable quality and long life. A reliable 3-year warranty.
voltages and capacities used in FA applications.
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W.
Appearance: insert type.
Control supply voltage: AC100/110/120V.
Action elements: overload detection.
Action characteristic: instantaneous action type.
Especially suitable for single phase motor over current protection.
Can be used for motor overload protection, common single-phase circuit of the AC current detection S8FS-C02505J.
A variety of models, such as anti time limit characteristics, lock time, instantaneous action, etc
S8FS-C02505J, are provided,
The product is rich in variety, and can be effectively protected, detected and controlled according to the actual situation.
When the current is large, the input resistance of the CT or the relay part is not needed, and the use is simple.
Because it is a plug-in, installation, disassembly, wiring and other operations are very simple S8FS-C02505J. Control power supply voltage: 125 VDC.
Input: DC or AC (selectable), Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) S8FS-C02505J.
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: Straight/Straight.
Cable diameter: 6.0 mm dia.
No. of cable cores: 4.
Cable core cross sectional area: 0.5 mm.
Cable length: 10 m.
DC: Minimum order, 1.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements aand ensure a,
94V-0 fire retardant rating S8FS-C02505J.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of CConnector Assembly: Crimping, soldering, and screw-on S8FS-C02505J.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.