LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
R87T-A6A15MP AC Axial Fans
OMRON R87T-A6A15MP Manual And Instructions
R87T-A6A15MP datasheetPDF datasheet
R87T-A6A15MP Connection Guide

OMRON R87T-A6A15MP Product information and technical parameters:
Brand: OMRON
Name: AC Axial Fans
Model: R87T-A6A15MP
Rated voltage: 230 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.100 A; 60 Hz, 0.085 A .
Rated input: 50 Hz, 16 W; 60 Hz, 14 W.
Rated rotational speed: 50 Hz, 2350 r/min; 60 Hz, 2750 r/min.
Maximum flow rate: 50 Hz, 1.7 m3/min; 60 Hz, 2.0 m3/min.
Maximum static pressure: 50 Hz, 36.7 Pa; 60 Hz, 37.3 Pa.
Noise: 50 Hz, 36 dB; 60 Hz, 40 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics.

Cable length L: A, 1.0 m; B, 0.75 m; C, 1.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase) R87T-A6A15MP.
Output specifications: Two transistor outputs R87T-A6A15MP
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control R87T-A6A15MP.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@) R87T-A6A15MP. Power ratings: 240 W.
Output voltage: 48 V.
Output current: 5 A (100 VAC) 6.3 A (200 VAC).
Boost current: 10 A.
Newly Released High-capacity 240-W Models in S8EX-series Lineup.
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models.
Lineup of models with from 5 to 48-VDC output.
voltages.
All Models.
Approved standards:
UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC.
Complies with harmonic current standard in EN.
61000-3-2 (50-W to 240-W models).
The top class in industry for compact size.
Boost current output (some models excluded). Open circuit mode: current circuit breaker.
Appearance: ADR shell.
Rated current: AC110V.
Rated frequency: 50/60Hz.
Consume VA: action time 10VA below (except for reactor part).
Action current adjustment range (zero phase converter primary current):
0.1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: 1A; closed circuit 110V 15A DC 1000 (L/R=0ms),
Open 110V 1A DC 1000 (L/R=25ms).
The relay control output circuit breaker switch: power capacity, switching capacity, AC110V/10A C110V/10A; (COS =1).
Quality: about 1kg.
EExternal: Mount Searl N1 R87T-A6A15MP. 5.
High voltage grounding relay type K2GA thin,
Miniaturization, and digital type precision mounting.
Strong anti interference ability,
Stable operation in the arc grounding fault.
Can carry out fine current adjjustment, easy to coordinate R87T-A6A15MP.
Set alarm terminal.
The adjusting part of the action current is a rotary switch mode, which is convenient for adjustment.