LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
R87T-A1A15HP AC Axial Fans
OMRON R87T-A1A15HP Manual And Instructions
R87T-A1A15HP datasheetPDF datasheet
R87T-A1A15HP Connection Guide

OMRON R87T-A1A15HP Product information and technical parameters:
Brand: OMRON
Name: AC Axial Fans
Model: R87T-A1A15HP
Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.250 A; 60 Hz, 0.210 A .
Rated input: 50 Hz, 20 W; 60 Hz, 18 W.
Rated rotational speed: 50 Hz, 2700 r/min; 60 Hz, 3100 r/min.
Maximum flow rate: 50 Hz, 2.6 m3/min; 60 Hz, 3.0 m3/min.
Maximum static pressure: 50 Hz, 66.6 Pa; 60 Hz, 58.8 Pa.
Noise: 50 Hz, 42 dB; 60 Hz, 46 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics.

Type: Medium-sensitivity models.
Sensed current: 100 mA/200 mA (switchable).
Type: Delayed models.
Operating time: 0.3/0.8 s (switchable).
Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages.
Performs continuous monitoring and detection of ground faults,
in low-voltage circuits due to the deterioration of insulation in,
electrical devices R87T-A1A15HP R87T-A1A15HP
Higher reliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutually compatible.
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease R87T-A1A15HP. Cable core number: 4.
Cable lead direction: straight line type.
Cable length: 5m.
Save time, save maintenance cost,
With a waterproof connector environment and strong tolerance of FA.
For IP67, the FA 94V-0 connector small special flammability.
The wiring system makes the device more maintainable connector,
And reduce the downtime of equipment.
Introduction of connector and modular connector with cable R87T-A1A15HP.
A modular connector crimping type, welding type, screw connection type 3.
With the cable connector is obtained UL certification of products.
According to IEC61076-2-101 (IEC60947-5-2), NECA4202. Power ratings: 240 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 24 V.
Output current: 10 A.
Boost Current: 12 A.
Reliable and Easy Operation-Worldwide Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC).
DC input can be available: 90 to 350 VDC.
Possible for 2-phase input usage.
Wide operation temperature range: –40 to 70 °C.
Power Boost function at 120%.
Safety standards:
UL508/60950-1, CSA C22 R87T-A1A15HP. 2 No. 107.1/60950-1.
EN50178, EN60950-1.
Lloyd’s standards, EN60204-1 PELV.
Safety of Power Transformers: EN61558-2-16.
ANSI/ISA 12.12.01 (excluding 480-W models).
CSA C22.2 No.213 (excluding 4800-W models) R87T-A1A15HP.
15-W,30-W, and 60-W models conform to.
UL Class 2 output Standards.
EMS: EN 61204-3.
EMI: EN 61204-3 Class B.
Three years Warranty *1.


...More relevant models >>>>