LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
R87F-A6A93LP AC Axial Fans
OMRON R87F-A6A93LP Manual And Instructions
R87F-A6A93LP datasheetPDF datasheet
R87F-A6A93LP Connection Guide

OMRON R87F-A6A93LP Product information and technical parameters:
Brand: OMRON
Name: AC Axial Fans
Model: R87F-A6A93LP
Rated voltage: 230 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.045 A; 60 Hz, 0.040 A .
Rated input: 50 Hz, 7 W ; 60 Hz, 6 W .
Rated rotational speed: 50 Hz, 1900 r/min; 60 Hz, 2200 r/min.
Maximum flow rate: 50 Hz, 0.7 m3/min; 60 Hz, 0.8 m3/min.
Maximum static pressure: 50 Hz, 24.5 Pa; 60 Hz, 34.3 Pa.
Noise: 50 Hz, 29 dB; 60 Hz, 32 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics.

Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 35 W.
Output voltage: 5 V.
Output current: 7 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V) R87F-A6A93LP.
Easy Mounting: Front-mounted type, DIN rail-mounted type are available R87F-A6A93LP
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA) R87F-A6A93LP.
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).No. of poles: 4.
Suitable cable dia: 4 mm dia. model (4 to 5 mm dia.).
Suitable core size: 0.18 to 0.75mm.
Suitable Sheath material: PVC, PE, PUR.
L-shaped connectors (for DC).
Minimum order: 50.
Water- and Environment-resistive FA R87F-A6A93LP.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Capacity: 480 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Maximum cutoff output current (per branch): 3.8 A.
Total output current: 20 A.
Number of output branches: 8 branch outputs.
Communications functions: None.
Parameter settings: Not changeable .
A New Type of Power Supply That.
Provides Safety and Maintainability. R87F-A6A93LP.
240- and 480-W power supplies with and digital circuit,
protectors in a single package.
Each branch output tripping current value can be easily,
set at 0.1-A increments.
Startup and shutdown sequence control included.
Various moonitor displays and alarms (output voltage,
output current, maintenance forecast monitor,
temperature) R87F-A6A93LP.
Conforms to UL Class 2.
Mounts to DIN Rail.


...More relevant models >>>>