LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
R87F-A6A93HP AC Axial Fans
OMRON R87F-A6A93HP Manual And Instructions
R87F-A6A93HP datasheetPDF datasheet
R87F-A6A93HP Connection Guide

OMRON R87F-A6A93HP Product information and technical parameters:
Brand: OMRON
Name: AC Axial Fans
Model: R87F-A6A93HP
Rated voltage: 230 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.055 A; 60 Hz, 0.050 A .
Rated input: 50 Hz, 13 W ; 60 Hz, 11 W .
Rated rotational speed: 50 Hz, 2550 r/min; 60 Hz, 3050 r/min.
Maximum flow rate: 50 Hz, 0.9 m3/min; 60 Hz, 1.0 m3/min.
Maximum static pressure: 50 Hz, 49.0 Pa; 60 Hz, 68.6 Pa.
Noise: 50 Hz, 33 dB; 60 Hz, 36 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics.

Power ratings: 30 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V.
Output current: 1.3 A.
UL Class 2 Output standards: Yes.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for R87F-A6A93HP.
Easy System Commissioning.
New 90-W models with indication monitor that R87F-A6A93HP
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC R87F-A6A93HP.
(Not compliant with EC Directives and other safety standards.) Type: open type.
Structure: bottom mounting type.
Capacity: 150W.
Output voltage: 5V.
Output current: 27A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function R87F-A6A93HP.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Cable Specifications: Fire-retardant, Robot cable.
No. of connector poles: 4.
Cable connection direction: Straight.
No. of cable cores: 2.
Cable outer diameter: 6.0 mm dia.
Cable core cross-sectional area: 0.5 mm.
Cable length: 0.3 m.
DC: Model.
Minimum order: 10.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements aand ensure a,
94V-0 fire retardant rating R87F-A6A93HP.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of CConnector Assembly: Crimping, soldering, and screw-on R87F-A6A93HP.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.


...More relevant models >>>>