Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.048 A; 60 Hz, 0.041 A .
Rated input: 50 Hz, 7 W ; 60 Hz, 6 W .
Rated rotational speed: 50 Hz, 2600 r/min; 60 Hz, 3000 r/min.
Maximum flow rate: 50 Hz, 0.6 m3/min; 60 Hz, 0.7 m3/min.
Maximum static pressure: 50 Hz, 39.2 Pa; 60 Hz, 53.9 Pa.
Noise: 50 Hz, 32 dB; 60 Hz, 36 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
environment.
Shaft supported by ball bearings for highly-reliable operation.
(28 type) included in series.
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
product. Check the information given for available models of Axial fans and,
the information in Characteristics.
Power ratings: 30 W.
Output voltage: 15 V.
Output current: 2 A.
Boost current: --.
Newly Released High-capacity 240-W Models in S8EX-series Lineup.
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models R87F-A4A83H.
Lineup of models with from 5 to 48-VDC output.
voltages
R87F-A4A83H
All Models.
Approved standards:
UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC.
Complies with harmonic current standard in EN.
61000-3-2 (50-W to 240-W models) R87F-A4A83H.
The top class in industry for compact size.
Boost current output (some models excluded). Type: collection type.
Enclosure: surface type.
30 years of best-selling products new upgrade in the reservation,
Based on the basic functions to achieve a compact.
The installation dimensions of the surface type remain unchanged, the volume ratio of the volume ratio of the square body is reduced,
Half R87F-A4A83H. (excluding AGD-U2)
Built in digital filter to reduce the impact of high frequency interference, to achieve a higher accuracy,
Leakage monitoring.
The output point consists of 1c1a * monitoring circuit, an external signal based on contact,
Remote monitoring and alarm output of each monitoring circuit.
Cube embedded type also built-in buzzer. (except AGD-U2) alarm output,
Optional external buzzer.
After the upgrade of all products can choose automatic reset, manual reset.
(AGD-N5, AGD-NY5, AGD-N52)Rated voltage: 200 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3000 r/min.
Maximum flow rate: 50 Hz, 3.5 m3/min; 60 Hz, 4.0 m3/min.
Maximum static pressure: 50 Hz, 68 Pa; 60 Hz, 63 Pa.
Noise: 50 Hz, 50 dB; 60 Hz, 53 dB.
Weight: Approx. 3410 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-ccut to,
simplify installation work R87F-A4A83H.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and VVent Attachment R87F-A4A83H.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades.