LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
R87F-A3A85LP AC Axial Fans
OMRON R87F-A3A85LP Manual And Instructions
R87F-A3A85LP datasheetPDF datasheet

OMRON R87F-A3A85LP Product information and technical parameters:
Brand: OMRON
Name: AC Axial Fans
Model: R87F-A3A85LP
Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.080 A; 60 Hz, 0.070 A .
Rated input: 50 Hz, 7 W ; 60 Hz, 6 W .
Rated rotational speed: 50 Hz, 2200 r/min; 60 Hz, 2500 r/min.
Maximum flow rate: 50 Hz, 0.6 m3/min; 60 Hz, 0.7 m3/min.
Maximum static pressure: 50 Hz, 25.0 Pa; 60 Hz, 32.0 Pa.
Noise: 50 Hz, 26 dB; 60 Hz, 29 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics.

Type: S8JC-Z series models list.
Meet the criteria: No.
Configuration: power supply with cover; bottom surface mounting.
Input voltage: 350W.
Output voltage: 5VDC.
Output current: 50.0A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time R87F-A3A85LP R87F-A3A85LP Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485 R87F-A3A85LP.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement R87F-A3A85LP.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Power ratings: 50 W.
Output voltage: 24 V.
Output current: 2.1 A.
Boost current: 4.2 A.
Newly Released High-capacity 240-W Models in S8EX-series Lineup.
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models.
Lineup of models with from 5 to 48-VDC output.
voltages.
All Models.
Approved sttandards:
UL60950-1, cUR CSA C22 R87F-A3A85LP. 2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC.
Complies with harmonicc current standard in EN R87F-A3A85LP.
61000-3-2 (50-W to 240-W models).
The top class in industry for compact size.
Boost current output (some models excluded).


...More relevant models >>>>