LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
R87F-A3A15LP AC Axial Fans
OMRON R87F-A3A15LP Manual And Instructions
R87F-A3A15LP datasheetPDF datasheet

OMRON R87F-A3A15LP Product information and technical parameters:
Brand: OMRON
Name: AC Axial Fans
Model: R87F-A3A15LP
Rated voltage: 230 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.072 A; 60 Hz, 0.064 A .
Rated input: 50 Hz, 11 W ; 60 Hz, 10 W .
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2250 r/min.
Maximum flow rate: 50 Hz, 2.0 m3/min; 60 Hz, 2.1 m3/min.
Maximum static pressure: 50 Hz, 44.1 Pa; 60 Hz, 44.1 Pa.
Noise: 50 Hz, 36 dB; 60 Hz, 38 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics.

Category: incidental cover type.
Structure: DIN guide rail mounting type.
Capacity: 50W.
Output voltage: 24V.
Output current: 2.2A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function R87F-A3A15LP.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity R87F-A3A15LP
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock R87F-A3A15LP.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"
Type: Static R87F-A3A15LP.
Number of digits: 2.
Compact (Two-, Three-, or Four-digit) S2-series,
Added to Static Mother Board.
Models.
Easily connect a M7E Digital Display without soldering.
Two-, three- and four-digit Mother Boards are available for,
connecting M7E Digital Displays and, by using two Mother,
Boards, two- to eight-digit displays are possible.
The depth of the Mother Board with M7E Digital Display,
Units is only 58 mm, ideal for mounting to compact or thin control panels.
Connecting to OMRON''s PLCs via dedicated PLC cables,
(sold separately) (refer to M7E Options). Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily becausse operation time,
is indicated from the start of operation R87F-A3A15LP.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions R87F-A3A15LP. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,