Rated voltage: 200 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2300 r/min; 60 Hz, 2600 r/min.
Maximum flow rate: 50 Hz, 0.8 m3/min; 60 Hz, 1.0 m3/min.
Maximum static pressure: 50 Hz, 41 Pa; 60 Hz, 45 Pa.
Noise: 50 Hz, 41 dB; 60 Hz, 44 dB.
Weight: Approx. 1150 g.
Easy One-step Mounting.
simplify installation work.
convenience in confined spaces.
mounting screws).
Optional Replacement Filter and Vent Attachment.
metal blades.
Models: F.
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular R87B-TA4A15MPFR.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system
R87B-TA4A15MPFR
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries R87B-TA4A15MPFR.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring R87B-TA4A15MPFR. Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Detected voltage: AC.
Compact, Economical Plug-inn Type Voltage R87B-TA4A15MPFR.
Sensing Relay.
DPDT output contacts expand the application of the Sensor to,
wide-ranging fields including control, alarms, and indication.
Voltage control is possible in the same easy manner as electro,
magneticc relays, as the output relay of the sensor can be driven,
directly with a detection signal R87B-TA4A15MPFR.
Wide voltage setting range with fine setting capability.