Number of beams: 100.
Protective height: 2000mm.
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
MS4800-RM6 Resource Module.
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
to set functions.
Direction of Operation Key insertion: Vertical.
Cable length: 1 m.
1NC/1NO(Slow-action).
Slim Safety Door Switches with IP67 Rating.
Slim design with a width of only 17 mm.
(three-contact models).
Reversible design allowing either front or rear mounting.
Built-in Switches with two- or three-terminal contact MS4800A-30-2000.
construction are available.
Operation Key with rubber mounting hole to absorb vibration and shock
MS4800A-30-2000
IP67 degree of protection. Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 5-contact Model,
Insert the built-in switch (E, F, G or H) into the blank @ MS4800A-30-2000.
Conduit size (See Note.): G1/2.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices MS4800A-30-2000.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors. Release key type: Special release key.
Indicator: Green.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+2NC/1NO.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns MS4800A-30-2000.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas. MS4800A-30-2000.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection.