With shell models have AC4 rated specifications (50/60Hz AC200/220V, 50/60Hz AC100/110V).
Standard type, with shell type, special contact specifications, double contact type, double coil latch type, etc., the product is complete.
International Standards for G3B Series,
Same Profile as MK Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”).
Plug-in type, same size as MK Power Relays.
Operation indicator provided to confirm input.
DC Output model available with 3 to 125-VDC load voltage,
range for high-voltage applications MK2P-DO. Isolation: Phototriac coupler
MK2P-DO
Zero cross function: NO.
Indicator: NO.
Rated output load: 3 A at 100 to 240 VAC *1 .
Rated input voltage: 12 VDC.
New Models with International Standards.
Added to G3H Series (-VD in model number).
Same Profile as LY1 and LY2 Bi-power.
Relays.
Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”) MK2P-DO.
Socket type, same size as LY Power Relays.
Operation indicator provided to confirm input,
(models numbers with “N” before the suffix). Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 75 A at 200 to 480 VAC (See note 2.).
Rated input voltage: 100 to 240 VAC.
Wide Lineup of General-purpose Solid State MK2P-DO.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Number of phase: Single-phase.
Control terminal block: Screwless clamp terminal block.
Type: Constant current.
Capacity: 45 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cyycle control MK2P-DO.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control MK2P-DO.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.