Signaling Circuits.
contact pressure for high durable.
Excellent resistance to vibration and shock.
Built-in operation indicators for simple operation verification.
Same external shape with the MK Power Relays.
Input terminals: Screwless clamp terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 25 A, 200 to 480 VAC.
A New-concept SSR with Built-in MK2KP Series.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection
MK2KP Series
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws MK2KP Series.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. The main body: with shell type / socket terminal type.
Category: Standard type.
Pole number: 2 pole.
A variety of eight pin pin type electric power.
With shell models have AC4 rated specifications (50/60Hz AC200/220V, 50/60Hz AC100/110V) MK2KP Series.
Installation, wiring convenient, easy to operate.
Has more than 5 million mechanical life, durable.
Standard type, with shell type, special contact specifications, double contact type, double coil latch type, etc., the product is complete. Standard certification: No.
Insulation mode: three end two-way photoelectric switch.
Zero trigger function: No.
Action indicator: No.
Applicable load of output: AC100 3A ~ 240V.
Input rated voltage: DC12V.
With the LY1, LY2 large power relay with the same shape of the G3H series, the new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with LY (1 pole, 2 pole type).
A model with an action indicator to check the status of the input. (type N)Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Applicable load: 25 A, 100 to 240 VAC.
Compacct, Slim-profile SSRs with Heat,
Sinks MK2KP Series. Models with No Zero Cross for,
a Wide Range of Applications.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output cuurrents MK2KP Series. (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification).