Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Pulse interval measurement range, the maximum measurable range from 10ms to 3200s.
Timer input: AC/DC multi-voltage input(24 to 240 VAC/VDC).
Display: 7-segment LCD.
Time range: 999h59min59s ←→ 9999h59.9min(switchable); Light-gray body.
Seven digits, time range 0 to 3999d23.9h.
Dual time range: 999999.9 ←→ 3999d23.9h or,
999h59m59s ←→ 9999h59.9m. Operating modes: Flicker ON start K3HB-PNB-A1 AC100-240.
Supply voltage: 100 to 240 VAC/100 to 125 VDC, 24 to 48 VAC/12 to 48 VDC
K3HB-PNB-A1 AC100-240
0.05 s to 300 h models: 8-pin models.
DIN 48 × 48-mm Twin Timers.
Wide power supply ranges of High Voltage 100 to 240 VAC/100,
to 125 VDC and Low Voltage 24 to 48 VAC/12 to 48 VDC.
ON- and OFF-times can be set independently and so,
combinations of long ON- or OFF-time and short OFF- or ON,
time settings are possible K3HB-PNB-A1 AC100-240.
Twenty-four time ranges from 0.05 s to 300 h depending on the,
model to be used.
Models with a flicker ON start or flicker OFF start are available.
Easy sequence checks through instantaneous outputs for a,
zero set value at any time range.
Length, when panel-mounted with a Socket, of 80 mm or less.
11-pin and 8-pin models are available. Input type: PNP input type.
Event input terminal 5 points (HOLD, RESET) equipped with K3HB-PNB-A1 AC100-240.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum can be measured from 10ms to 3200DIN 48 × 48-mm Twin Timers.
Wide power supply ranges of High Voltage 100 to 240 VAC/100,
to 125 VDC and Low Voltage 24 to 48 VAC/12 to 48 VDC.
ON- and OFF-times can be set independently and so,
combinations of long ON- or OFF-time and short OFF- or ONN,
time settings are possible K3HB-PNB-A1 AC100-240.
Twenty-four time ranges from 0.05 s to 300 h depending on the,
model to be used.
Models with a flicker ON start or flicker OFF start are available.
Easy sequence checks through instantaneous outputs for a,
zero set value at any time range K3HB-PNB-A1 AC100-240.
Length, when panel-mounted with a Socket, of 80 mm or less.
11-pin and 8-pin models are available.