K3HB-PNB-A1 AC/DC24V Time interval table
OMRON K3HB-PNB-A1 AC/DC24V Manual And Instructions
K3HB-PNB-A1 AC/DC24V datasheetPDF datasheet

OMRON K3HB-PNB-A1 AC/DC24V Product information and technical parameters:
Brand: OMRON
Name: Time interval table
Model: K3HB-PNB-A1 AC/DC24V
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum measurable range from 10ms to 3200s.
6 measurement methods,

Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with.
External power supply DC12V80mA.
Communication: RS-232C; NPN open collector (OUT5, OUT4, OUT3, OUT2, OUT1).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed pulse K3HB-PNB-A1 AC/DC24V.
Measuring, increasing or decreasing pulse meter.
Action determine the color, can switch the green / Red 2 kinds of color display K3HB-PNB-A1 AC/DC24V
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
Cumulative pulse input is 50kHz, the phase difference pulse is 25kHz,Input type: DC current input.
Output type: BCD+ transistor; -; NPN open collector (5 bit output +HH, PASS, L, LL) K3HB-PNB-A1 AC/DC24V.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display K3HB-PNB-A1 AC/DC24V.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DProject: Japanese specification model.
Installation method: surface /DIN rail installation (agreement type) horizontal.
All day control operation is simple
Can be carried out on the choice of a few weeks of action. (but only 1 of the week moves and all week specific dates can be set)
ON/OFF time setting has 24 steps.
Consistent with CE markers. Through the UL, CSA standard certification.
Rest day function can be easily carried out on holidays, such as the setting of a sudden break.
Test mode function cann easily confirm the program K3HB-PNB-A1 AC/DC24V.
Can also be used to deal with a sudden change in the way of a semi automatic work.
The pulse action can cope with daylight saving time.
All models are equipped with finger protection function.
Produuct series contains embedded installation, surface mount, the size of the agreement and other ways K3HB-PNB-A1 AC/DC24V.
The same setting can be done with the timer action.