LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
K2CU-P4A-B Heater Element Burnout Detector
OMRON K2CU-P4A-B Manual And Instructions
K2CU-P4A-B datasheetPDF datasheet

OMRON K2CU-P4A-B Product information and technical parameters:
Brand: OMRON
Name: Heater Element Burnout Detector
Model: K2CU-P4A-B
Control supply voltage: 110/220 VAC; With voltage fluctuation compensation.
Operating current: 2 to 4 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.

Connector type: Plug and socket on cable ends.
Cable connection direction: Straight.
Applicable wire diameter: --.
Number of cores: 8.
Cable length: 2 m.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating K2CU-P4A-B.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime K2CU-P4A-B
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. No. of poles: 4.
Connection method: Crimping K2CU-P4A-B.
Suitable cable dia: 4 mm (4 to 5).
Core conductor size: 0.18 to 0.3, 0.5 to 0.75 *2.
Suitable sheath material: PVC, PE, PUR.
Straight Connectors.
Minimum order: 50.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock K2CU-P4A-B.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.097 A; 60 Hz, 0.080 A .
Rated input: 50 Hz, 7 W ; 60 Hz, 6 W .
Rated rotational speed: 50 Hz, 2600 r/min; 60 Hz, 3000 r/min.
Maximum flow rate: 50 Hz, 0.6 m3/min; 60 Hz, 0.7 m3/min.
Maximum static pressure: 50 Hz, 39.2 Pa; 60 Hz, 53.9 Pa.
Noise: 50 Hz, 32 dB; 60 Hz, 36 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and mmetal-bladed models,
(28 type) included in series K2CU-P4A-B.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certiffied safety standards depend on the,
product K2CU-P4A-B. Check the information given for available models of Axial fans and,
the information in Characteristics.


...More relevant models >>>>
Last one: OMRON K2CU-P4-A
next one: OMRON K2CU-P4-B