H7CN-TXL Solid-state Counter
OMRON H7CN-TXL Manual And Instructions
H7CN-TXL datasheetPDF datasheet
H7CN-TXL User's Manual

OMRON H7CN-TXL Product information and technical parameters:
Brand: OMRON
Name: Solid-state Counter
Model: H7CN-TXL
Classification: Totalizing Counter.
Input signal system (Count & reset inputs): Contact/Transistor.
Mounting method: Flush mounting, surface mounting.
Display: 7-segment LEDs (10 mm high).
Number of digits: 4 digits (0 to 9,999).
Backup power for memory protection: Yes.
Control output: --.
Operating mode: Up counting.
Max.counting speed: 30 cps.
All Required Counter Functions.
Incorporated in a Compact DIN-sized.
(48 × 48) Housing.
In addition to Up and Down models, a reversible (Up-Down),
counter is also available.
Maximum counting speed of 5,000 cps, never before attained by,
a small-size preset counter.
Power supply freely selectable within a range of 100 to 240 VAC.
Also, power supply for the DC-operated models is selectable,
within a range of 12 to 48 V.
Models with memory backup function against power failure available.

Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified H7CN-TXL H7CN-TXL
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Can enter DC0.001mSupply voltage: 12 VDC H7CN-TXL.
Control output: Contact output, DPDT (time-limit DPDT,
or time-limit SPDT + instantaneous SPDT) Changed using a switch.
Four-mode Timer.
Multiple time ranges and operating modes let you cover a wide,
range of applications.
The time-limit DPDT output contacts can be changed to time-limit,
SPDT and instantaneous SPDT output contacts using a switch.
Sequence checks are easily performed by setting an instanta,
neous output to 0 H7CN-TXL.
Start signal control for the H3DK-M. Large Setting Dial and Moving Pointers Ideal,
for Easy Operation and Monitoring.
Incorporating an easy-to-see large setting dial with moving pointers.
Wide time-setting range of 0.2 s to 60 h.
(available through three time-range model types).
Wide AC power supply range (100 to 240 VAC).
IP65 watertight and dust-tight front panel.
Approved by UL and CSA.
Conforms to EN61812-1 and IEC60664-1.
4 kV for Low Voltage, and EMC Directives H7CN-TXL.
Conforms to EMC standards.
Six-language instruction manual provided.
Programmable contact enables the building of a self-holding,
relay circuit as well as built-in instantaneous contact. (-NS).
Memory reteention (-NSR) H7CN-TXL.
Finger protection terminal block.
Enables easy sequence checks through instantaneous outputs.
for a zero set value at any time range.