Control cycle: Yearly.
Number of outputs: 2 circuits.
Mounting method: Surface mounting/track mounting.
Supply voltage: 24 VDC.
Addition to 2-circuit Weekly Models.
Independent Day Keys provide easier operation.
output for holidays and non-operating days.
Settings can be made even with the Time Switch turned OFF.
Test mode enables easy program checking.
Complies with EMC Directives, UL/CSA, and other safety standards.
Includes summer time (DST) adjustment.
Yearly models also offer automatic switching to DST.
Set value can be changed both upward and downward for speedier setting.
accurate time over a wide temperature range. (See note 1.)
indicator. (See note 2.)
Bank function allows program switching by an external input.
size added to the series.
Input type: DC current input.
Output type: linear; voltage; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with H5S-YFB2D-X.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
H5S-YFB2D-X
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNeInput type: PNP input type H5S-YFB2D-X.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Linear: current; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table H5S-YFB2D-X.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximum measurable from 10mUnit: CPU Units.
Name: Standard LCD type.
No. of I/O points: 20.
LCD display: Yes.
Power supply voltage: 12 to 24 VDC.
Inputs: 12, 12 to 24 VDC.
Outputs: 8, Transistors.
Buttons, calendar, and clock: Yes.
Analog input: Yes.
Even Broader Applications with Increased.
Functionality and Higher Precision.
Increased functionality in a compact body (70 mm wide × 90 mm high).
Easy programming is available using the LCD and operation,
buttons. (See note 1.).
This single Unit easily provides relay, timer, counter, and time,
switch functions.
Expansion is easy with Expanssion I/O Units, allowing up to 44,
I/O points H5S-YFB2D-X. (See note 2.).
Economy-type and Communications-type CPU Units have been,
added to series.
Improved Weekly Timers (See note 1.).
Increased timing accuracy with a monthly deviation of ±155 s,
max H5S-YFB2D-X. Multiple-day operation and pulse output operation have,
been added.
Select from two power supply options:
100 to 240 VAC or 12 to 24 VDC.