Easy to Use and Easy to Read.
Basic Features.
Character height of 10 mm for better readability.
Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Safety and Reliability.
Power supply circuit and input circuits are isolated for safety and reliability.
Set value limit function prevents unexpected operation of output devices.
caused by setting mistakes.
the load.
Other Features.
Models with instantaneous contact output.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection.
Control cycle: a week.
Output number: 2 channel.
Installation method: embedded installation.
Power supply voltage: AC100 ~ 240V.
Japanese label model.
The new standard for use of more convenient timing switches.
On the basis of a week of 2 channel type, the output of 4 channel type / year type also joined the series H5CZ Series.
Use the independent key to improve the working performance significantly
H5CZ Series
Holiday, holiday and other output OFF have a simple holiday set function.
Power OFF can also be set.
Test mode that can be easily recognized by the program.
In accordance with UL/CSA, electrical safety standard certification, EMC standards.
Industry first
Can reduce the set value, achieve fast setting!
The built-in temperature compensation circuit, even in a larger temperature range,
Can also achieve highCount input: PNP/NPN universal DC voltage input (4 H5CZ Series. 5 to 30 VDC).
Display: 7-segment LCD with backlight.
Max. revolutions displayed (applicable encoder resolution):
1000 s–1 (1 pulse/rev.), 1000 min–1 (60 pulse/rev.); Black body.
Revolutions displayed up to five digits.
Dual revolution display according to encoder resolution used;
1000 s–1/1000 min–1 or 1000 H5CZ Series. 0 s–1 /1000.0 min–1,
Switchable dual revolution display type available (-NV1 models);
extended up to 10000 min–1. Timer input: No-voltage input.
Display: 7-segment LCD.
Time range: 999h59min59s ←→ 9999h59.9min(switchable); Light-gray body.
Seven digits, time range 0 to 3999d23.9h.
Dual time range: 999999.9 ←→ 3999d23.9h or,
999h59m59s ←→ 9999h59.9m. Type of input: AC voltage input.
Output type: communication; RS-232C; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not eqquipped with H5CZ Series.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend H5CZ Series.
External event input can be applied to a variety of measurement and identification situations.
Dev