resetting/external, resetting (see note 2).
Operation mode: 8 operation modes (selectable)(see note 3).
Terminal: 11-pin round socket.
Time-limit contact: SPDT.
Instantaneous contact: --.
Mounting: Surface mounting/track mounting; Flush mounting.
DIN-sized (48 x 48, 45 x 75 mm) Timer with.
Digital Setting and LCD Display.
Dual power supplies for free AC/DC.
Eight operation modes selectable with one unit.
seconds to 9,990 hrs.
Four external signal inputs.
remaining time.
Conforms to UL, CSA, and CE marking.
Type of input: AC current input.
Output type: transistor; -; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth H3CA-A .
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
H3CA-A
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet type systemOperating method: Reversible (selectable with rotary DIP switch) between,
0 and the set value; Incrementing/decrementing A/D (command inputs);
Incrementing/decrementing B/E (individual inputs);
Incrementing/decrementing C/F (phase difference inputs) H3CA-A .
Mounting method: Flush mounting.
Operation modes: N, F, C, R, K, P, Q (selectable with rotary DIP switch).
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L) H3CA-A .
Control output: 1-stage counters: Contact (SPDT) and transistor,
output (H and L output switchable);
2-stage counters: Contact (SPST-NO) and transistor output,
(H and L output switchable).
Set value read: Continuous mode.
Memory backup: No .
Display: Yes (10-mm high 7-segment LED, Up indicator).
Models: 4 digits; 1 stage.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking. Count input: PNP/NPN universal DC voltage input (4.5 to 30 VDC).
Display: 7-segment LCD with backlight.
Max. revolutions displayed (applicablee encoder resolution):
1000 H3CA-A . 0 s–1 (10 pulse/rev.), 1000.0 min–1 (600 pulse/rev.),
←→10000 min–1 (60 pulse/rev.) (switchable). ; Black body.
Revolutions displayed up to five digits.
Dual revolution display according to encoder resolution used;
1000 s–1/1000 min–1 or 1000 H3CA-A . 0 s–1 /1000.0 min–1,
Switchable dual revolution display type available (-NV1 models);
extended up to 10000 min–1.