LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
GX-OD3218 Digital I/O Terminal 3-tier Terminal Block Type
OMRON GX-OD3218 Manual And Instructions
GX-OD3218 datasheetPDF datasheet
GX-OD3218 PROGRAMMING MANUAL
GX-OD3218 INSTRUCTION MANUAL
GX-OD3218 Safety Precautions

OMRON GX-OD3218 Product information and technical parameters:
Brand: OMRON
Name: Digital I/O Terminal 3-tier Terminal Block Type
Model: GX-OD3218
Input capacity: 32 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the G terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 100 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 210 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.

Classification: For output.
Internal I/O circuit common: NPN (– common).
I/O points: 8 output points.
Connector Connection Models that.
Allows Easy Connection to Sensors and Output Devices.
Sensors with easy-to-wire connectors are easily,
attached or detached.
Connects to 2-wire sensors.
Remote teaching of the Sensor Terminal is possible GX-OD3218.
with the PLC by using output signals of the Sensor Terminal GX-OD3218
DIN track mounting and screw mounting are available. Unit: Connector model.
I/O classification: Digital input.
Internal I/O common: PNP (- common).
I/O points: 16.
I/O connections: Molex connector.
Power supplyvoltage: 24 VDC.
I/O specification: DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available GX-OD3218.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires.
DIN track mounting. Name: e-CON Connectors.
Specifications: Inputs/Outputs;
16 inputs /16 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection GX-OD3218.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Input 8 points corresponding to NPN (+ public)
Remote I/O terminal (transistor connnector type 4 point /8 point)
Achieve business card in half the size of the connector input type
Can switch between long range / high speed communication mode GX-OD3218.
A product with 4 points and 8 points.
Save space.
Small size of X H45mm W58mm.

Through the cable leads to the direction of the reunification of the above, can reduce the occupied area GX-OD3218.
With input short circuit protection function.


...More relevant models >>>>
Last one: OMRON GX-ID3228