LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
GT1-TS04T Temperature Input Units
OMRON GT1-TS04T Manual And Instructions
GT1-TS04T datasheetPDF datasheet
GT1-TS04T HOST CONNECTION MANUAL
GT1-TS04T INSTRUCTION MANUAL

OMRON GT1-TS04T Product information and technical parameters:
Brand: OMRON
Name: Temperature Input Units
Model: GT1-TS04T
I/O classification: Temperature inputs.
I/O points: 4 inputs.
I/O connections: Terminal block.
Power supply voltage: 24 VDC.
Input specification: Thermocouple.
Temperature Input Units for use with MULTIPLE I/O TERMINAL.
Four inputs.
Thermocouples and platinum resistance thermometer models,
are available.
Conversion time is only 250 ms for 4 inputs.
The Configurator can be used to calibrate temperatures.
The circuit section can be removed, so rewiring isn’t,
required during maintenance.
DIN track mounting.

Input type: Platinum-resistance thermometer input.
I/O points: 4 inputs allocated 4 input words at the Master Unit,
(8 input words allocated when 1/100 display mode is selected).
Temperature Input Terminal with Smart Functionality.
The Temperature Input Terminal can be used with almost the same functionality as a GT1-TS04T.
Analog Input Terminal, such as with scaling and comparator functions.
Enhanced performance is provided with functionality specific to the Temperature,
Input Terminal, such as the recording the operating time in a preset temperature,
range and temperature difference detection between input channels GT1-TS04T
Name: Clamp Terminal Blocks.
Specifications: Outputs; 8 outputs ; PNP; -- GT1-TS04T.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error GT1-TS04T. I/O classification: Input.
Internal I/O circuit common: PNP (– common).
I/O points: 8.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported. Classification: For output.
Internal I/O circuit common: NPN (– common).
II/O points: 8 output points GT1-TS04T.
Connector Connection Models that.
Allows Easy Connection to Sensors and Output Devices.
Sensors with easy-to-wire connectors are easily,
attached or detached.
Connects to 2-wire sensors.
Remote teaching oof the Sensor Terminal is possible GT1-TS04T.
with the PLC by using output signals of the Sensor Terminal.
DIN track mounting and screw mounting are available.


...More relevant models >>>>
Last one: OMRON GT1-DA04
next one: OMRON GT1-TS04P